mckero 65e50c0065 Stop cleanup killing unrelated processes, and recover when it happens anyway
Two faults that combined to take the web UI down twice in one session, each time
surfacing to the user as a 502 through the reverse proxy.

`pkill -f 'M uv-k5-v3'` in run.sh and trace_run.sh matched far more than intended.
-f tests the whole command line, so it also matched the shell running the pkill
(the pattern sits in its own argv), any script mentioning the machine type, and the
QEMU child of a running webui.py. Cleanup now lives in tools/lib_kill_emulator.sh:
pgrep -x on the binary name, confirm uv-k5-v3 in /proc/PID/cmdline, and optionally
scope to one QMP socket so a caller only stops the instance it owns.

The supervisor then could not recover from it. power_on() began with
`if self._client is not None: return False`, but a client object is not proof of a
live guest -- after an external kill the stale client made power_on refuse forever,
so the Power button was dead until the whole service was restarted. It now checks
whether the process actually exited and relaunches, logging why.

Tests:

- tools/test_kill_emulator.sh checks a plain process, a process whose command line
  merely mentions uv-k5-v3, and the calling script all survive; that a real emulator
  on a named socket is stopped; that one on another socket is not; and that an
  unscoped call still clears everything. Verified it leaves a live webui.py alone.
- Two supervisor unit tests cover relaunch-after-external-kill and the case that
  must still refuse, so this cannot regress into starting two emulators at once.

Verified end to end against the running web UI: kill the emulator from outside,
status reports unreachable, and pressing Power brings it back to
{"status":"running"} where before it stayed dead.

While writing the first version of the test I modelled the failure as a client
raising BrokenPipeError, which is not what is_running() looks at -- it checks
poll(). The mock was wrong, not the code; the test now has the process report an
exit status, which is what really happens.
2026-08-28 15:50:13 +01:00

205 lines
7.4 KiB
Python

#!/usr/bin/env python3
"""Owns the QEMU process, so the web UI can power the emulator on and off.
QMP `quit` stops the emulator but also destroys the socket, so nothing is left to
receive a later "power on". Power control therefore needs something outside the
QMP connection that can spawn the process again -- that is this.
Off then On is a cold boot: the process is replaced and the guest starts from
reset, the same as cutting mains power and restoring it. `system_reset` is the
warm alternative and keeps the process.
`adopt()` covers the other case: the server attached to an emulator someone else
started with run.sh. Then `power_off` must refuse, because we did not start that
process and killing it is not ours to do.
"""
import os
import socket
import subprocess
import threading
import time
DEFAULT_QMP = "/tmp/uvk5-qmp.sock"
def default_launcher(qemu: str, flash: str, elf: str,
qmp_path: str = DEFAULT_QMP, gdb_port: int = 1234,
capture_stderr: bool = True):
"""Reproduces the command line in tools/run.sh."""
def launch():
# A stale socket makes QEMU fail to bind, which looks like "power on did
# nothing". Clear it first.
if os.path.exists(qmp_path):
os.unlink(qmp_path)
return subprocess.Popen(
[qemu, "-M", f"uv-k5-v3,flash-image={flash}",
"-nographic", "-monitor", "none",
"-qmp", f"unix:{qmp_path},server=on,wait=off",
"-kernel", elf, "-gdb", f"tcp::{gdb_port}"],
stdout=subprocess.DEVNULL,
stderr=subprocess.PIPE if capture_stderr else subprocess.DEVNULL)
return launch
def wait_for_socket(path: str, timeout: float = 15.0) -> bool:
"""Wait until something is actually accepting connections on `path`.
Existence is not enough. A unix socket file outlives the process that created
it, so a crashed or killed emulator leaves one behind, and a plain
os.path.exists() check returns immediately and the connect then fails with
ECONNREFUSED -- which surfaces as power on returning 500. Probing with a real
connect distinguishes "listening" from "leftover file".
"""
deadline = time.monotonic() + timeout
while time.monotonic() < deadline:
if os.path.exists(path):
probe = socket.socket(socket.AF_UNIX, socket.SOCK_STREAM)
try:
probe.settimeout(1.0)
probe.connect(path)
return True
except OSError:
pass # stale, or not listening yet
finally:
probe.close()
time.sleep(0.05)
return False
class Supervisor:
def __init__(self, launch, connect, log=None):
self._launch = launch
self._connect = connect
self._log = log
self._lock = threading.Lock()
self._proc = None
self._client = None
def _note(self, text: str):
"""Record a power event, if anyone is collecting them."""
if self._log is not None:
self._log.add("power", text)
def is_running(self) -> bool:
with self._lock:
if self._client is None:
return False
# A process that exited on its own is not running, whatever we think.
if self._proc is not None and self._proc.poll() is not None:
return False
return True
def owns_process(self) -> bool:
"""True when we launched it, and may therefore stop it."""
with self._lock:
return self._proc is not None
def client(self):
with self._lock:
return self._client
def process(self):
with self._lock:
return self._proc
def adopt(self, client):
"""Use an emulator we did not start. power_off will refuse to kill it."""
with self._lock:
self._client = client
self._proc = None
def power_on(self) -> bool:
with self._lock:
# A client object is not proof of a live guest. If the process died
# behind our back -- crashed, OOM-killed, or caught by someone else's
# cleanup -- the stale client made this return False forever, so the
# Power button did nothing until the whole service was restarted.
# Observed twice for real.
if self._client is not None and self._proc is not None \
and self._proc.poll() is not None:
self._note(f"emulator exited on its own "
f"(status {self._proc.returncode}); restarting")
self._client = None
self._proc = None
if self._client is not None:
return False
self._proc = self._launch()
try:
self._client = self._connect()
except Exception as exc:
# Do not leave a half-started emulator behind: the process would
# keep running with no client tracking it, hold the QMP socket, and
# block the next power on. Clean up and report instead.
proc, self._proc = self._proc, None
self._client = None
if proc is not None:
proc.terminate()
try:
proc.wait(timeout=5)
except Exception:
proc.kill()
self._note(f"power on failed: {exc}")
raise
proc = self._proc
self._note("power on")
# Forward QEMU's own stderr, which run.sh and the tests used to discard.
# Firmware serial arrives here too, tagged SERIAL by the machine model.
if self._log is not None and getattr(proc, "stderr", None) is not None:
threading.Thread(
target=self._log.pump_stream, args=(proc.stderr,),
kwargs={"default_source": "qemu"}, daemon=True).start()
return True
def power_off(self) -> bool:
with self._lock:
client, proc = self._client, self._proc
self._client, self._proc = None, None
if client is None:
return False
try:
client.command("quit")
except Exception:
# Expected: quit tears the socket down, often before the reply.
pass
try:
client.close()
except Exception:
pass
code = None
if proc is not None:
try:
code = proc.wait(timeout=10)
except Exception:
proc.terminate()
try:
code = proc.wait(timeout=5)
except Exception:
proc.kill()
self._note("power off" if code in (None, 0)
else f"power off (qemu exited with {code})")
return True
def reset(self) -> bool:
"""Warm reboot, or a cold boot when the emulator is off."""
client = self.client()
if client is None:
return self.power_on()
client.command("system_reset")
self._note("reset")
return True
def pause(self) -> bool:
client = self.client()
if client is None:
return False
client.command("stop")
return True
def resume(self) -> bool:
client = self.client()
if client is None:
return False
client.command("cont")
return True